<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15341</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Error: request to rotate plate when rotator not properly installed
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Remove the plate from the machine and select "PLATE CLEARED" button on
the workstation dialog box.  Call Creo Service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
The system wants to rotate the plate currently on the unload table, but
the rotator is not installed in firmware.  Check the rotator_installed
parameter (set al ri) and the rotate_plate parameter for the plate on the
unload table (set state plate_loc u rp).
</text></DescriptionText>
<DescriptionText><text>
If plates are to be rotated, set the 'al ri' (rotator installed) parameter
to 1 and save the value (nvs save al ri).
</text></DescriptionText>
<DescriptionText><text>
If plates are not to be rotated, set the bay rotate_plate parameter to 0
(set state bay 1 rp 0).  Any plates picked from the bay will now be set up
to not be rotated.
</text></DescriptionText>
<DescriptionText><text>
It may be useful to set the 'verbose alcmd' and 'verbose alconv 'parameters to 1
in order to obtain further diagnostic information.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The rotate_plate parameter may be set to 1 with the rotator_installed parameter
still at 0.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/process.xml</LinkAddress><LinkTitle>Command: process</LinkTitle></Link>
<Link><LinkAddress>../commands/clear.xml</LinkAddress><LinkTitle>Command: clear</LinkTitle></Link>
Command:   set state bay 1
Command:   set state plate_loc u
<Link><LinkAddress>../nvs/al_cfg_ri.xml</LinkAddress><LinkTitle>NVS: al ri</LinkTitle></Link>
<Link><LinkAddress>../nvs/bay_state_rp.xml</LinkAddress><LinkTitle>NVS: bay rp</LinkTitle></Link>
<Link><LinkAddress>../nvs/plate_loc_state_rp.xml</LinkAddress><LinkTitle>NVS: plate_loc rp</LinkTitle></Link>
<Link><LinkAddress>../nvs/verbose_cfg_alcmd.xml</LinkAddress><LinkTitle>NVS: verbose alcmd</LinkTitle></Link>
<Link><LinkAddress>../nvs/verbose_cfg_alconv.xml</LinkAddress><LinkTitle>NVS: verbose alconv</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:03 2008 PST
</Updated>
<Links>
</Links>
</Error>